Line Pump vs Boom Pump: Which Is Right for Your Job?

How big a stone can a 3-inch pump line carry? Under the American Concrete Pumping Association (ACPA) one-third rule, the answer is 1 inch (3 / 3 = 1). That rule, plus a few sourced figures, explains more about the two pump types than their names do.

Quick Answer

The ACPA operator study guide (version 03.11) says a line pump moves grout or a 3/8-inch pea gravel mix through 2, 2-1/2 or 3 inch pipe and hose. A boom pump is a truck-mounted pump with a placing boom. Reach, output and aggregate limits differ by model.

What Is a Line Pump?

A line pump, in the ACPA operator study guide (version 03.11), pumps grout or a 3/8-inch pea gravel mix through pipe and hose that is 2, 2-1/2 or 3 inches in diameter. The guide lists small interior or exterior slabs, shotcreting, block filling, tank filling, pressure grouting and soil stabilization among its uses.

The same guide gives setup advice for trailer pumps. Place the pump where two ready-mix trucks can reach it, if possible, and keep the placing line "as short and straight as possible". ACPA says pumping through rubber hose is three times as hard as through steel pipe. So 10 feet of rubber hose equals 30 feet of pipe in pumping effort (10 x 3 = 30).

Note that "trailer pump" and "line pump" are not strictly the same thing. The ACPA guide also names a trailer pump with a placing boom.

What Is a Boom Pump?

A boom pump is a truck-mounted concrete pump with an articulating placing boom. The ACPA guide refers to three-, four- and five-section boom pumps. No ACPA boom-pump definition was read, so none is attributed to ACPA here.

Putzmeister describes its BSF 38-5 as a truck-mounted pump for medium to high-volume concrete pours. That description covers that model only. To budget a pump job once you know the type, the Concrete Pump Cost Calculator exists for that purpose; the type facts here come from ACPA and Putzmeister, not from the tool.

Line pump and boom pump, with the source for each cell
Item Line pump Boom pump
Definition ACPA guide: grout or 3/8-inch pea gravel mix through 2, 2-1/2 or 3 inch pipe and hose ACPA guide names three-, four- and five-section boom pumps; no ACPA definition read
Uses stated ACPA guide: small slabs, shotcreting, block and tank filling, pressure grouting, soil stabilization Putzmeister BSF 38-5 page: medium to high-volume pours
Piston face pressure ACPA guide: high-pressure trailer pumps can exceed 2000 PSI; not stated for other line pumps ACPA guide: most boom pumps 700 to 1000 PSI
Placing method Pipe and hose laid out from the pump (ACPA guide) Placing boom; the BSF 38-5 has five arms and a 4 m end hose (Putzmeister)
Power lines Not stated for line pumps in the sources read ACPA: boom never within 20 ft of energized overhead lines
Two pump set-ups, illustrative Left: a pump on wheels at ground level with a hose laid along the ground to a pour area. Right: a truck with a boom unfolded up and over to a pour area. Illustrative, not to scale, no numbers. Two set-ups (illustrative, not to scale) Ground pump, hose to the pour Truck with unfolded placing boom
Illustrative sketch only; it shows set-up, not size, reach or output.

How Does Aggregate Size Set the Line Diameter?

ACPA says the placing line should be at least three times, and preferably four times, the size of the largest aggregate in the mix. The guide also frames it the other way: the largest coarse aggregate is limited to one-third of the smallest inside diameter of the pump or placing line.

The sums below are arithmetic on ACPA’s rule, not extra ACPA figures:

  1. ACPA’s own example. 1-1/2 in aggregate x 3 = 4-1/2 in minimum line (1.5 x 3 = 4.5).
  2. The preferred four times. 1-1/2 in x 4 = 6 in (1.5 x 4 = 6).
  3. Pea gravel. 3/8 in x 3 = 1-1/8 in (0.375 x 3 = 1.125); 3/8 in x 4 = 1-1/2 in (0.375 x 4 = 1.5).
  4. A 3 in line, worked backward. 3 / 3 = 1 in aggregate at the three-times rule; 3 / 4 = 0.75 in at the four-times rule.
Line diameter from the ACPA three-times and four-times rule Scale 50 px per inch. 3/8 inch aggregate: 1.125 inch at 3x, 1.5 inch at 4x. 1 inch aggregate: 3 inch at 3x, 4 inch at 4x. 1-1/2 inch aggregate: 4.5 inch at 3x, 6 inch at 4x. Arithmetic on the ACPA rule. Line diameter from the ACPA rule (arithmetic) One scale for every bar: 50 px per inch of line diameter 3/8 in aggregate x 3 1.125 in 3/8 in aggregate x 4 1.5 in 1 in aggregate x 3 3 in 1 in aggregate x 4 4 in 1-1/2 in aggregate x 3 4.5 in 1-1/2 in aggregate x 4 6 in
Teal bars are the three-times minimum; amber bars are the preferred four times.

What Do Two Putzmeister Models Show?

Putzmeister’s published figures show how far apart two pumps can sit, and each belongs to its own model. Reach, output and aggregate limits differ by model, so neither set below stands for all pumps.

  • Putzmeister BSF 38-5 (truck-mounted boom pump). Vertical reach 37.5 m and horizontal reach 32.8 m, with a DN 125 delivery line. Output is 160 to 170 cubic meters per hour depending on configuration. The page states no maximum aggregate size.
  • Putzmeister TK 20 (Thom-Katt trailer-mounted concrete/shotcrete pump). Output up to 13 cubic meters per hour, delivery pressure 139 bar, maximum aggregate 25 mm and a 102 mm pressure connection.

My arithmetic, not Putzmeister’s: 37.5 m x 3.281 = 123.0 ft; 32.8 m x 3.281 = 107.6 ft; 125 mm / 25.4 = 4.9 in; 25 mm / 25.4 = 0.98 in (about 1 in); 102 mm / 25.4 = 4.0 in.

The TK 20 is a high-pressure grouting and shotcrete trailer pump. Putzmeister calls it suited to wet-process refractory, underground and civil work. It is not a typical slab line pump, and its 4.0 in connection is larger than the 2, 2-1/2 and 3 inch sizes in ACPA’s line-pump definition. Both pages read were Putzmeister regional sites (Turkey and Southeast Asia) with metric specifications.

What Safety Rules Apply to Boom Pumps?

ACPA’s position is that placing booms shall never be operated within 20 feet of energized overhead power lines, or 50 feet when the voltage exceeds 350 kV. ACPA also says contact with high-voltage power lines is the most common cause of fatal and serious accidents involving placing booms.

ACPA minimum boom distance from energized overhead lines Scale 10 px per foot. 20 feet is the ACPA limit for placing booms near energized overhead power lines. 50 feet applies when the voltage exceeds 350 kV. ACPA: never operate a placing boom closer than this One scale for both bars: 10 px per foot 20 ft (ACPA) 50 ft above 350 kV (ACPA)
Both distances are ACPA’s; the second applies only above 350 kV.

The study guide adds that a dedicated spotter is employed when wires are within 20 feet of the area to be poured. ACPA also says to tell the pumping company about power lines when ordering the pump and to remind the operator on arrival.

For the ground, the guide says to extend all outriggers fully and use the manufacturer’s pads, even on concrete. Relocate the pump when the outriggers cannot be stabilized. The guide says truck-mounted boom pumps are required to be level within three degrees. Near an open cut, set the outriggers back at least the depth of the ditch. The guide also states that a boom of 50 m or larger can put over 60,000 pounds on one outrigger.

What Does ACPA Say About Pumpable Mixes?

ACPA says the properties of the fine aggregate matter more than the coarse aggregate when proportioning pumpable mixes. The guide adds that an admixture that improves workability generally improves pumpability.

On air, the guide says entrained air up to six percent generally makes a mix more pumpable, while low-slump mixes above eight percent air are difficult to pump. This article states no slump number because none was read for ordinary pumped concrete.

On water, ACPA says it should only be added by the contractor or a designated representative. Excess water raises the water-cement ratio, which can lead to lower strength and excessive shrinkage. The operator may advise on mix design or slump, but the guide gives the contractor final responsibility. For the water side of a mix, see how much water per bag. For how ready-mixed concrete differs from bagged mix, see ready-mix vs bagged concrete.

Check your pump options

The pump calculator’s Not sure option suggests a line or boom pump from volume and reach. Its thresholds are its own and are not verified here. To size the pour first, use the concrete volume and ordering calculators.

FAQs About Line Pumps and Boom Pumps

What is a line pump?

ACPA’s operator study guide (version 03.11) defines it as a pump for grout or a 3/8-inch pea gravel mix through 2, 2-1/2 or 3 inch pipe and hose. Listed uses include small slabs, shotcreting, block filling and grouting.

What is a boom pump?

A boom pump is a truck-mounted pump with a placing boom. The ACPA study guide mentions three-, four- and five-section boom pumps. Reach, output and aggregate limits differ by model, so read the model’s own specifications.

What size hose does a line pump use?

ACPA’s line-pump definition covers pipe and hose of 2, 2-1/2 or 3 inches. Putzmeister’s TK 20 trailer pump lists a 102 mm pressure connection, about 4.0 in by arithmetic, which is larger than those sizes.

How big can the aggregate be in a pumped mix?

ACPA says the placing line should be at least three times, preferably four times, the largest aggregate. By arithmetic, a 3 inch line takes 1 inch aggregate at three times and 0.75 inch at four times.

How far can a boom pump reach?

It depends on the model. Putzmeister lists the BSF 38-5 at 37.5 m vertical and 32.8 m horizontal reach, about 123.0 ft and 107.6 ft by arithmetic. Other models differ.

How close can a boom get to power lines?

ACPA says a placing boom shall never be operated within 20 feet of energized overhead power lines, or within 50 feet when the voltage exceeds 350 kV.

Can the pump operator add water to the mix?

ACPA says water should only be added by the contractor or a designated representative. Excess water raises the water-cement ratio, which can lower strength and increase shrinkage.

Sources and Further Reading

References Used in This Article

This article summarizes ACPA guidance and figures for two named Putzmeister models, not every pump. Pump limits depend on the model and the line size, so confirm reach, hose size and aggregate with your pumping contractor. Reviewed for accuracy by Prof. Dr. Khalil Mudassar, PhD. Last updated 2026-10-21.