What Is Lightweight Concrete?

How light can structural concrete get? FHWA says all-lightweight concrete may reach 0.090 kcf, nearly a 40 percent reduction from a typical normal-weight 0.145 kcf. Sources do not agree on one density line, so this guide keeps each definition with the group that wrote it.

Quick Answer

Lightweight concrete is concrete made with low-density aggregate so it weighs less than normal concrete. ACI’s FAQ puts the structural ceiling at an air-dried density of 115 lb/ft3, with strength above 2,500 psi. AASHTO, quoted by FHWA, uses a different ceiling: 0.135 kcf, which is 135 lb/ft3.

What Counts as Lightweight Concrete?

It depends on who is defining it, because the density ceilings differ. ACI’s free FAQ page says structural low-density (lightweight) concrete is made with low-density aggregate having an air-dried density of not more than 115 lb/ft3 and a 28-day compressive strength of more than 2,500 psi.

AASHTO’s definition, as quoted in the FHWA Lightweight Concrete Bridge Design Primer (FHWA-HIF-19-067, November 2021), is concrete with lightweight aggregate meeting AASHTO M 195 and an equilibrium density not exceeding 0.135 kcf, as determined by ASTM C567. A kcf is 1,000 lb per cubic foot, so 0.135 kcf is 135 lb/ft3 (our arithmetic).

The ACI ceiling (115) and the AASHTO ceiling (135) are not the same number. ACI states an air-dried density and AASHTO an equilibrium density. A third source, CIP 36 from the Concrete in Practice series (a hosted copy that does not name its publisher), also asks for strength above 2,500 psi.

Who states what about lightweight concrete (each density stays with its own source)
Source What it states Density as stated
ACI FAQ Definition of structural low-density concrete; strength above 2,500 psi at 28 days Air-dried density of not more than 115 lb/ft3
AASHTO, as quoted by FHWA Definition of lightweight concrete; aggregate to AASHTO M 195 Equilibrium density not exceeding 0.135 kcf
CIP 36, Concrete in Practice series Structural lightweight versus normalweight; strength above 2,500 psi In place, 90 to 115 lb/ft3 versus 140 to 150 lb/ft3
FHWA primer Bridge lightweight concrete versus normal-weight 0.110 to 0.125 kcf, as low as 0.090 kcf, versus 0.140 to 0.155 kcf

How Much Lighter Is It Than Normal Concrete?

Each source gives its own range, so there is no single figure. CIP 36 says structural lightweight concrete has an in-place density on the order of 90 to 115 lb/ft3, against 140 to 150 lb/ft3 for normalweight concrete.

FHWA says bridge lightweight concrete typically runs 0.110 to 0.125 kcf (110 to 125 lb/ft3, arithmetic), and normal-weight concrete 0.140 to 0.155 kcf. ESCSI, the trade association of the makers of expanded shale, clay and slate aggregate, says structural lightweight concrete is typically 25% to 35% lighter, with strengths comparable to normal weight.

FHWA’s lightest case is all-lightweight concrete at 0.090 kcf against a typical 0.145 kcf. By our arithmetic, (145 – 90) / 145 = 37.9 percent, which matches FHWA’s wording “nearly a 40 percent reduction”. The Concrete Weight Calculator multiplies a volume by a density you choose. Its lightweight preset is its own value of 115 lb per cu ft, while the sources above give ranges.

Stated densities by source, lb/ft3 One scale, 7 px per lb/ft3, starting at 80 lb/ft3. CIP 36 lightweight 90 to 115. FHWA bridge lightweight 110 to 125. ACI air-dried ceiling at 115. AASHTO equilibrium ceiling at 135 (0.135 kcf). CIP 36 normalweight 140 to 150. FHWA normal-weight 140 to 155. Stated densities by source (lb/ft3) CIP 36 lightweight, in place: 90 to 115 FHWA bridge lightweight: 110 to 125 (0.110 to 0.125 kcf) ACI ceiling, air-dried: 115 (marker, not a range) AASHTO ceiling, equilibrium: 135 (0.135 kcf; marker, not a range) CIP 36 normalweight: 140 to 150 FHWA normal-weight: 140 to 155 (0.140 to 0.155 kcf) 80 100 120 140 160 Scale: 7 px per lb/ft3 from 80. Each source measures density its own way.
The ranges overlap in places, but each belongs to its own source and is not merged.

What Are the Types of Lightweight Concrete?

FHWA names three informal types, defined by which aggregate is lightweight. It says the terms may still be used informally but are not used in the specifications.

  • All-lightweight. Both the coarse and the fine aggregate are lightweight. FHWA calls it the lightest type of structural concrete.
  • Sand-lightweight. The coarse aggregate is lightweight and the sand is normal weight. FHWA says it is currently the most widely used.
  • Specified-density. Any blend of conventional and lightweight aggregates, to reach a specified density.

CIP 36 says the lightweight aggregates are typically expanded shale, clay or slate fired in a rotary kiln to make a porous structure, and that air-cooled blast furnace slag is also used. ESCSI, the aggregate makers’ trade association, describes the same shale, clay and slate material, expanded in a rotary kiln.

CIP 36 also mentions non-structural lighter concretes, such as cellular concrete, that are used for insulation. This guide gives no density for them. For plain concrete versus cement and mortar, see concrete vs cement vs mortar.

Which aggregate is lightweight (illustrative) Illustrative schematic, no numeric scale. All-lightweight: coarse and fine aggregate both lightweight. Sand-lightweight: coarse aggregate lightweight, sand normal weight. Specified-density: any blend of lightweight and conventional aggregates. Which aggregate is lightweight (illustrative) All-lightweight Coarse aggregate: lightweight Fine aggregate: lightweight Sand-lightweight Coarse aggregate: lightweight Sand: normal weight Specified-density Any blend of lightweight and conventional aggregates Type names as used informally by FHWA. Teal: lightweight. Amber: normal weight. Not to scale. Schematic only: the boxes show which aggregate is lightweight, not amounts.
Illustrative: the type name tells you which aggregate is lightweight.

Where Is It Used, and How Strong Is It?

Sources say structural lightweight concrete can reach strengths similar to normal concrete. CIP 36 says mixtures can be designed for similar strengths, and ACI and CIP 36 both set a structural floor of more than 2,500 psi.

FHWA says all structural lightweight aggregates can produce design strengths above 5.0 ksi (5,000 psi, arithmetic) and 6.0 ksi is widely available. It gives a practical current maximum of 10 ksi, or 10,000 psi.

CIP 36 says the primary use is reducing the dead load of a structure. It lists bridge decks, piers and beams, slabs and walls in frame buildings, parking structures, tilt-up walls and topping slabs. ESCSI, the aggregate makers’ trade association, lists floors on steel deck, parking structures, precast elements, marine structures, and fill and insulating concrete.

FHWA reports one old example: the San Francisco-Oakland Bay Bridge upper deck of 1936 used lightweight concrete at 0.095 kcf (95 lb/ft3, arithmetic), and FHWA says that deck is still in service.

How Is It Handled Differently?

The main differences are pre-wetting, air entrainment and pumping. This is not a mix design, only what the sources say.

CIP 36 says lightweight aggregates generally need wetting before use, and that absorption is typically 5% to 20% by weight of dry aggregate. It also says virtually all lightweight concrete is air-entrained, and that air content must be controlled so the density requirement is met.

For pumping, both CIP 36 and FHWA say to pre-soak the aggregate, because pump pressure drives water into the pores and can cause slump loss. CIP 36 adds that excess water or slump lets the lightweight aggregate separate from the mortar.

CIP 36 also says design generally relies on equilibrium density, which is approximately 3 to 8 lb/ft3 below the fresh density, and that the correlation should be agreed before delivery. For bag weights of other mixes, see how many bags are on a pallet. Masonry units are a separate topic: see concrete block sizes.

What Does a Cubic Yard Weigh? A Worked Example

The weight of a cubic yard is volume times density, and the answer moves with the density you pick. These are labelled arithmetic sums, not weights that any source prints.

  1. Convert the volume. 1 cubic yard = 3 x 3 x 3 = 27 cu ft.
  2. Normal weight at the tool default. 27 x 150 = 4,050 lb.
  3. Lightweight at the tool preset. 27 x 115 = 3,105 lb, which is 4,050 – 3,105 = 945 lb less.
  4. CIP 36 lightweight range. 27 x 90 = 2,430 lb to 27 x 115 = 3,105 lb per cubic yard.
  5. CIP 36 normalweight range. 27 x 140 = 3,780 lb to 27 x 150 = 4,050 lb per cubic yard.
One cubic yard weight by volume times density (arithmetic) One scale, 0.15 px per lb from zero. Tool normal-weight 150 lb/ft3: 4,050 lb. Tool lightweight preset 115 lb/ft3: 3,105 lb. CIP 36 lightweight 90 to 115 lb/ft3: 2,430 to 3,105 lb. CIP 36 normalweight 140 to 150 lb/ft3: 3,780 to 4,050 lb. One cubic yard (27 cu ft), volume x density Tool default, 150 lb/ft3: 4,050 lb Tool lightweight preset, 115 lb/ft3: 3,105 lb CIP 36 lightweight, 90 to 115 lb/ft3: 2,430 to 3,105 lb CIP 36 normalweight, 140 to 150 lb/ft3: 3,780 to 4,050 lb 0 1,000 2,000 3,000 4,000 Scale: 0.15 px per lb from zero (lb). Arithmetic, not printed by any source.
Same cubic yard, different densities: the weight follows the density you choose.
Try your own volume and density

Enter a volume and a density from your project or supplier in the weight calculator for concrete. For other quantities, see the concrete volume and ordering calculators.

FAQs About Lightweight Concrete

What is lightweight concrete?

Lightweight concrete is concrete made with low-density aggregate. ACI’s FAQ defines the structural kind as having an air-dried density of not more than 115 lb/ft3 and a 28-day strength of more than 2,500 psi.

How much lighter is it than normal concrete?

ESCSI, the aggregate makers’ trade association, says it is typically 25% to 35% lighter. FHWA says all-lightweight concrete at 0.090 kcf is nearly a 40 percent reduction from the typical 0.145 kcf.

What is lightweight concrete made of?

CIP 36 says the aggregates are typically expanded shale, clay or slate fired in a rotary kiln, and that air-cooled blast furnace slag is also used. The firing gives the particles a porous structure.

Is lightweight concrete as strong as normal concrete?

CIP 36 says mixtures can be designed for similar strengths as normalweight concrete. FHWA says all structural lightweight aggregates can reach design strengths above 5.0 ksi, with a practical maximum of 10 ksi.

What is sand-lightweight concrete?

FHWA describes it as lightweight coarse aggregate with normal-weight sand, giving an intermediate density. FHWA says it is currently the most widely used type of lightweight concrete.

Where is lightweight concrete used?

CIP 36 lists bridge decks, piers and beams, slabs and walls in frame buildings, parking structures, tilt-up walls and topping slabs. It says the primary use is reducing the dead load of a structure.

Does lightweight concrete need special handling?

CIP 36 says the aggregates generally need wetting before use and virtually all lightweight concrete is air-entrained. CIP 36 and FHWA both say to pre-soak the aggregate for pumping, because pump pressure drives water into the pores.

Sources and Further Reading

References Used in This Article

Sources define lightweight concrete by density and strength in different ways, so check the definition your project or supplier uses. The sums here are volume-times-density arithmetic, not a mix design. Reviewed for accuracy by Prof. Dr. Khalil Mudassar, PhD. Last updated 2026-10-21.