Does a post need the same footing as a wall? No. A post and a wall carry load differently, and the 2015 IRC treats them differently too.
A spread footing is an isolated concrete pad that carries one column or post. A continuous footing is a strip that runs under a wall. The 2015 IRC says exterior walls sit on continuous footings or other approved systems. It allows isolated plain concrete footings under columns only in narrow cases.
Spread Footing vs Continuous Footing by Load
The load decides the footing type. A spread footing carries the point load from one column or post. A continuous footing carries the line load from a wall along its full run.
The spread footing calculator works out the concrete for isolated pads. You enter the pad length, width, thickness and count, and the tool returns volume, bags and rebar. It does not handle wall strips.
| Footing | What it carries | Layout | How the spread tool counts it |
|---|---|---|---|
| Spread (isolated pad) | One column or post | One pad per column or post. The tool page also names a combined pad under two or more columns. | Pad volume times pad count, plus waste on concrete, then bags and bar length. |
| Continuous (strip) | A wall line | A strip under the wall. R403.1 of the 2015 IRC puts exterior walls on continuous footings or other approved systems. | Not counted by the spread tool. The tool page points strip mode to the Concrete Footing Calculator. |
When the Code Allows an Isolated Footing
The 2015 IRC requires continuous footings under exterior walls, or other approved systems. It allows isolated footings under columns only in a narrow case. This article quotes the 2015 text, a historical copy on the ICC site.
Section R403.1.3.6 holds that narrow case. It says “isolated plain concrete footings supporting columns or pedestals are permitted.” It covers detached one- and two-family dwellings of three stories or less with stud bearing walls.
The 2015 text allows this only under those conditions. The spread footing tool page states no such limit, so check these conditions yourself before you use its output. Local amendments can be stricter. This article did not verify any local rule, so check with your building department.
How Each Footing Is Laid Out
In plan view, each spread footing is a separate rectangle under one post. The tool takes one pad length, one pad width and a pad count, so every pad in a run has the same size.
A continuous footing is one long strip that follows the wall line. It is laid out as a run, not as a row of separate pads. This article gives no rule for where a wall meets a column. Ask an engineer about that junction.
How the Code Sizes a Column Footing
For piers and columns, the 2015 IRC sizes the footing from the tributary load and the allowable soil pressure. Table R401.4.1 gives presumptive soil bearing values in pounds per square foot (psf). Presumptive means the table assumes the value. It is not a measurement of your site.
The table lists these presumptive values, from the highest to the lowest:
- Crystalline bedrock: 12,000 psf
- Sedimentary and foliated rock: 4,000 psf
- Sandy gravel: 3,000 psf
- Sand, silty sand or clayey sand: 2,000 psf
- Clay or silt: 1,500 psf
The pad spreads the column load over an area of soil. The soil value sets how much pressure that soil can take, so softer soil needs a larger footing for the same load.
Quantities for a Four-Pad Example
The spread footing tool page uses four pads as its worked example. Each pad is 4 ft by 4 ft and 12 in thick, with 10 percent waste. These are the tool’s arithmetic examples, not recommended sizes. Every result below was checked by hand. The tool’s stated defaults are one pad, 12 in rebar spacing, 3 in cover and 10 percent waste. Its bag options are 80 lb, 60 lb and 40 lb bags, which hold 0.60, 0.45 and 0.30 cu ft.
- Volume per pad. 4 x 4 x 1 = 16 cu ft. Four pads: 16 x 4 = 64 cu ft.
- Add waste. 64 x 1.10 = 70.4 cu ft.
- Convert to cubic yards. 70.4 / 27 = 2.607, shown as 2.61 cu yd.
- Count bags. An 80 lb bag holds 0.60 cu ft. 70.4 / 0.60 = 117.3, so round up to 118 bags.
- Count rebar. Each pad has 4 bars each way at 12 in spacing. Each bar runs the 48 in pad side minus 3 in cover on each end, or 42 in (3.5 ft). Per pad: 8 bars x 3.5 ft = 28 ft. Four pads: 112 ft.
The tool page shows 4 x 4 bars per pad, but it does not state the bar length rule in step 5. That rule is inferred from the output. The tool applies waste to concrete, not to rebar.
The tool page’s FAQ gives a pad thickness range of 10 to 16 inches but cites no source for it. This article does not treat that range as a code rule.
Checks Before You Size a Footing
Start with the code your inspector enforces. The text in this article is a 2015 historical copy, so a newer edition or a local amendment may read differently.
Depth is a separate question. The guide on how deep footings should be covers it, so this article does not restate depth rules.
If your column sits in a sonotube, read the guide on whether sonotubes need a footing. This article does not cover sonotube design.
- Ask about the wall-to-column junction. This article gives no rule for it, so an engineer should decide.
- Check local amendments. None were verified here.
- Match the tool to the load. The spread tool covers isolated pads only.
Enter your pad size, pad count and waste in the pad volume and bar count tool to see concrete, bags and rebar for isolated footings.
FAQs About Spread and Continuous Footings
What is the difference between a spread footing and a continuous footing?
An isolated pad sits under one column or post, and a strip runs along a wall line. The 2015 IRC puts exterior walls on continuous footings, or other approved systems.
Can a column sit on an isolated footing instead of a continuous one?
Only in narrow cases. The 2015 IRC allows isolated plain concrete footings under columns or pedestals in some detached one- and two-family dwellings of three stories or less with stud bearing walls. Check local code.
How does the 2015 IRC size a footing for a column?
For piers and columns, it sizes the footing from the tributary load and the allowable soil pressure. Table R401.4.1 gives presumptive soil values, from 1,500 psf for clay or silt to 12,000 psf for crystalline bedrock.
Which edition of the code does this article quote?
This article quotes the 2015 IRC, Chapter 4 Foundations, a historical copy on the ICC website. The 2021 IRC page could not be read, so no 2021 wording is stated.
Does the spread footing calculator handle wall footings?
No. It handles isolated pads under columns or posts. For strips, the tool page points to the Concrete Footing Calculator.
Does the waste allowance apply to rebar?
No. In the tool’s four-pad example, the 10 percent waste applies to concrete only. The rebar total of 112 ft is shown with no waste added.
How many bags did the four-pad example need?
The example needs 118 bags of 80 lb each, at 0.60 cu ft per bag. The 70.4 cu ft with waste divided by 0.60 is 117.3, rounded up to 118.
Sources and Further Reading
References Used in This Article
The code text quoted here is the 2015 IRC, not the current edition. Check the code your inspector enforces before you size a footing. Reviewed for accuracy by Prof. Dr. Khalil Mudassar, PhD. Last updated 2026-11-11.

Shakeel Muzaffar is the Founder and Editor-in-Chief, with over 15 years of experience in digital publishing and online tool development. He oversees editorial quality and formula verification to ensure accurate, practical, and easy-to-use calculators.