What Is ICF? How Insulated Concrete Form Walls Work

What happens to the formwork after the concrete is poured? With ICF, which stands for insulated concrete forms, it stays in the wall as foam insulation. This guide sets out what an ICF wall is, how it is built and what named makers and government pages say about it.

Quick Answer

ICF stands for insulated concrete forms: hollow rigid foam blocks stacked like bricks, reinforced with steel rebar and filled with poured concrete. The foam stays in place as both formwork and insulation. Each maker states its own core, foam, R-value and pour rules, so follow your block maker’s manual and your engineer.

What Is an ICF Wall Made Of?

An ICF wall is a layer of foam, a concrete core and a second layer of foam. The U.S. Department of Energy’s Building Science Education Solution Center describes hollow rigid foam insulation blocks stacked like bricks to form walls, which are later reinforced with steel rebar and filled with poured concrete (DOE page, accessed 2026-10-21).

Makers describe the parts in their own words. NUDURA calls its forms stay-in-place permanent formwork for structural concrete, made of two expanded polystyrene (EPS) foam panels. Amvic describes two 2.5 in Type II EPS panels connected by polypropylene webs placed 6 in on center.

The forms remain after the concrete cures. NUDURA’s specification says the concrete must be protected by approved interior and exterior finish material, as it states all codes require. To count the blocks and core concrete for your own wall, use the ICF calculator for wall blocks and core concrete.

Illustrative ICF wall cross-section Not-to-scale sketch of one ICF wall. Left to right: inner EPS panel, concrete core crossed by web ties with two rebar dots, outer EPS panel. Text notes Amvic’s stated two 2.5 in EPS panels and webs 6 in on center. Illustrative cross-section of an ICF wall (not to scale) Inner EPS panel Concrete core Outer EPS panel Navy bars: web ties. Coral dots: steel rebar (positions illustrative). Amvic R22 states two 2.5 in EPS panels joined by webs 6 in on center.
A schematic of the parts named by the DOE and Amvic; no scale is implied.

What Do Two ICF Makers State for Their Blocks?

Each maker states its own figures, and the two products below differ in core, foam and block size. These are the numbers on the NUDURA XR35 data sheet and the Amvic R22 data sheet, accessed 2026-10-21.

Figures stated for two named products (not one “standard” ICF block)
Brand and product Core Foam Stated R-value Block size
NUDURA XR35 standard form 6 in (150 mm) or 8 in (200 mm) 4 in EPS panels “Minimum R-35” (RSI 6.16, U-Value 0.16) 96 in long, 18 in high
Amvic R22, straight 6 in core block 6 in Two 2.5 in Type II EPS panels “R-Value of 22” 48 x 16 x 11 in; 0.099 yd3 of concrete and 5.33 sq ft of wall face per block

NUDURA’s R-35 and Amvic’s R-22 are each that product’s own stated figure. The basis for NUDURA’s figure is not stated on the sheet, so this article does not treat it as foam alone. The two numbers are not compared, ranked or averaged here.

Foam and core inches by named product One scale, 32 px per inch. NUDURA XR35 with 6 in core: 4 in EPS, 6 in core, 4 in EPS, 14 in in all. NUDURA XR35 with 8 in core: 4, 8, 4, 16 in in all. Amvic R22 6 in core: 2.5, 6, 2.5, 11 in in all. Stated foam and core thickness (inches, one scale) NUDURA XR35, 6 in core EPS 4 Core 6 EPS 4 14 in NUDURA XR35, 8 in core EPS 4 Core 8 EPS 4 16 in Amvic R22, 6 in core EPS 2.5 Core 6 EPS 2.5 11 in Scale: 32 px per inch. Totals are the sum of the stated foam and core figures.
Stated foam and core inches for the two products; the sums match the 14 in, 16 in and 11 in widths on the sheets.

How Are ICF Walls Braced and Poured?

The blocks are braced, filled with concrete in lifts and vibrated. Sources describe the steps with different numbers, so the figures below stay with the document that states them.

The Building America Solution Center, run by Pacific Northwest National Laboratory (PNNL), says to brace the wall forms every 6 ft and to plan to get beyond the 32 in level with the first lift. It says most houses up to a 12 ft wall will need three passes, and that concrete should be vibrated unless a self-consolidating mix is used (PNNL page, accessed 2026-10-21).

Amvic’s installation manual says to pour with a boom pump in layers of about 3 to 4 ft and to use a pencil vibrator. It warns that leaving out the bracing will frequently produce a blowout. NUDURA’s specification recommends a boom pump and internal vibration. Lift height is therefore one maker’s instruction, not a universal rule.

Illustrative ICF pour sequence Four boxes in order. Brace: PNNL says every 6 ft. First lift: PNNL says beyond the 32 in level. Fill in lifts: Amvic says layers of about 3 to 4 ft. Vibrate: PNNL says unless a self-consolidating mix is used. Illustrative pour sequence (no scale) 1. Brace PNNL: braces every 6 ft 2. First lift PNNL: get beyond the 32 in level 3. Fill in lifts Amvic: layers of about 3 to 4 ft 4. Vibrate PNNL: unless the mix is self-consolidating Each figure belongs to the named source; the sources do not share one lift height.
The order of steps is illustrative; each number is the named source’s own.

What Concrete and Steel Do the Makers Call For?

Makers name their own concrete and steel requirements, and the numbers differ between documents. Follow the document for your own product and your local rules.

  • NUDURA’s specification. Concrete is specified as normal-weight, with maximum aggregate of 1/2 in for cores up to 6 in and 3/4 in for 8 in cores and beyond, and a minimum of 2,900 psi at 28 days. Walls are normally reinforced with deformed steel bars.
  • Amvic’s manual. Structures must be designed under the applicable building codes or a licensed professional engineer, and the code takes precedence over the manual.
  • Amvic’s US Design Guide. It reproduces the NAHB/PCA Prescriptive Method: flat ICF walls need a minimum concrete thickness of 5.5 in for basement walls and 3.5 in above grade. Maximum slump is 6 in, maximum aggregate is 3/4 in and minimum strength is 2,500 psi at 28 days.

The Prescriptive Method figures here come from Amvic’s reproduction. The original document could not be read for this article. A core thinner than 5.5 in sits below the basement figure, so the maker’s own manual and the local code govern.

What Do Energy Agencies Say About ICF Walls?

The DOE says ICFs have demonstrated a 9% better whole-wall R-value and are 10% more airtight, compared to stick-frame construction in otherwise identical homes. The PNNL page cites the same finding to a 1996 study.

Both pages credit the reinforced concrete with adding thermal mass. PNNL adds that ICF walls have almost no thermal bridging in the wall itself, and that final wall thickness is greater than 1 ft after finishes are applied. Both pages say to install ICFs according to the manufacturer’s specifications to get a continuous air barrier and thermal boundary.

These are comparisons with stick-frame homes in one cited study, not a rating for any one product. For where the wall sits, our guide on how deep footings should be covers the footing. For the masonry alternative, see concrete block sizes.

Worked Example: Blocks and Core Concrete for a 40 by 9 ft Wall

Take the ICF calculator’s default: a 40 ft by 9 ft wall with 30 sq ft of openings, 16 x 48 in blocks, a 6 in core and 5% waste on blocks and on concrete. This matches the dimensions of Amvic’s straight 6 in block. All sums below are arithmetic.

  1. Net wall area. 40 x 9 – 30 = 330 sq ft.
  2. Block face. 16 x 48 / 144 = 5.333 sq ft.
  3. Block count. 330 / 5.333 = 61.9, and 61.9 x 1.05 = 65 blocks.
  4. Layout. 108 in / 16 in = 6.75, so 7 courses. 40 ft is 480 in, and 480 / 48 = 10 blocks per course.
  5. Core concrete. 330 x (6 / 12) = 165 cu ft, and 165 / 27 = 6.11 cu yd. With 5% waste, 6.11 x 1.05 = 6.42 cu yd.

Cross-check with Amvic’s sheet: 6 x 16 x 48 = 4,608 cu in per block. One cubic yard is 46,656 cu in, so 4,608 / 46,656 = 0.0988 cu yd, which Amvic prints as 0.099 yd3. Then 65 blocks x 0.0988 = 6.42 cu yd, the same figure. Both numbers are gross volumes that do not allow for the webs.

Count your own wall

Enter your wall, openings and block size in the ICF block and concrete estimator. It has no insulation, R-value or rebar content. For footings, see the foundations and footings calculators.

FAQs About ICF Walls

What does ICF stand for?

ICF stands for insulated concrete forms. The DOE describes hollow rigid foam insulation blocks stacked like bricks, reinforced with steel rebar and filled with poured concrete.

What is inside an ICF wall?

Foam panels, a concrete core and reinforcement. Amvic’s R22 block joins two 2.5 in EPS panels with polypropylene webs 6 in on center, and NUDURA says its walls are normally reinforced with deformed steel bars.

How thick is the concrete core?

It depends on the product. NUDURA’s XR35 standard form has a 6 in or 8 in core, and Amvic’s straight R22 block described here has a 6 in core. Check your own maker’s sheet.

Are ICF walls reinforced with steel?

The DOE says the blocks are reinforced with steel rebar. NUDURA says its walls are normally reinforced, and Amvic says structures must be designed under building codes and a licensed professional engineer.

What concrete mix do ICF makers call for?

NUDURA’s specification gives a 28-day minimum of 2,900 psi, with 1/2 in maximum aggregate for cores up to 6 in. Amvic’s guide reproduces a 2,500 psi minimum and 3/4 in aggregate from the Prescriptive Method.

Is ICF more airtight than stick-frame?

The DOE says ICFs are 10% more airtight than stick-frame construction in otherwise identical homes, with a 9% better whole-wall R-value. The PNNL page cites that finding to a 1996 study.

What pour limits apply to an ICF wall?

Limits differ by source. Amvic pours in layers of about 3 to 4 ft. PNNL says to brace every 6 ft and expects three passes for most houses up to a 12 ft wall. Follow your maker’s manual.

Sources and Further Reading

References Used in This Article

This guide reports what two government pages and two named makers state, each tied to its own product. Each ICF maker states its own core, foam and pour rules, so follow your block maker’s manual and your engineer. Reviewed for accuracy by Prof. Dr. Khalil Mudassar, PhD. Last updated 2026-10-21.