How to Build a French Drain

How much fall does a French drain need? The City of Norfolk, Virginia, asks for at least 1 in of drop for every 8 ft of trench. Over a 50 ft run, that is about 6 in. Learning how to build a French drain is mostly about getting that slope, the trench size and the fabric right.

Quick Answer

To build a French drain, call 811, then dig a trench at least 12 in wide and 18 to 24 in deep that falls at least 1 in per 8 ft (Norfolk, Virginia). Line it with non-woven fabric, lay 2 to 3 in of washed gravel, set perforated pipe holes down, add gravel and fold the fabric over.

Check the Site Before You Dig

Two checks come first: underground utilities and groundwater. Norfolk’s homeowner guide tells you to call 811 before digging, so marked lines stay clear of your trench. Local permit rules still apply on top of it.

Next, dig a test hole. Norfolk says a test hole that fills with water means the water table is too shallow to build. Washington State University Extension in Clark County agrees in spirit: its guide says a French drain works best outside the groundwater table.

Every rule in this article is regional. The sources come from Virginia, Louisiana, Pennsylvania, Washington and Vermont, and they disagree on stone size, slope and fabric. Your local building or stormwater office decides what is allowed on your lot, so check with it before you order material.

How to Build a French Drain, Step by Step

The clearest homeowner sequence comes from Norfolk’s guide, dated 2023-04-12. The steps below follow it, with notes where other sources differ. To turn your own trench into gravel, pipe and fabric amounts, use the French drain gravel and pipe calculator.

  1. Mark and call. Mark the route of the trench and call 811 so utility lines get marked.
  2. Dig the trench. Make it at least 12 in wide and 18 to 24 in deep. Norfolk ties the depth to pipe size and foundation depth.
  3. Set the fall. Slope the bottom at least 1 in per 8 ft toward the outlet.
  4. Line it. Lay non-woven Class C geotextile in the trench. Overlap the ends at least 12 in, lapped in the direction of flow.
  5. Add a gravel bed. Spread 2 to 3 in of 1/2 to 3/4 in coarse, washed, screened gravel.
  6. Lay the pipe. Use 3 to 4 in perforated PVC or slotted corrugated pipe, with the holes facing down.
  7. Fill and wrap. Add gravel to 3 to 5 in below the top of the trench, then fold the fabric over the gravel.
French drain cross-section by source Main drawing, to scale for a 12 by 18 inch trench: Norfolk, Virginia calls for a trench at least 12 inches wide and 18 to 24 inches deep, a 2 to 3 inch gravel bed, a 3 to 4 inch perforated pipe with holes facing down, half inch to three quarter inch washed gravel ending 3 to 5 inches below the top, and non-woven fabric folded over the gravel. Inset: LSU AgCenter in Louisiana uses a trench 12 to 18 inches wide and 18 to 24 inches deep, about 1 inch washed gravel, a 4 inch pipe at the base, fabric on the base and walls only, and gravel that may run to the surface. French drain cross-section, per the Norfolk, VA guide At least 12 in wide 18 to 24 in deep Gravel ends 3 to 5 in below top Non-woven fabric folds over top 1/2 to 3/4 in washed gravel 3 to 4 in perforated pipe, holes facing down 2 to 3 in gravel bed under pipe Drawn to scale for a 12 x 18 in trench with a 4 in pipe. LSU AgCenter (Louisiana) differs on the fabric Fabric on base and walls only Gravel may run to the surface About 1 in washed gravel Trench 12 to 18 in wide, 18 to 24 in deep, 4 in pipe
Norfolk wraps the gravel in fabric; LSU lines only the base and walls.

How Wide and Deep Should the Trench Be?

For a home drain, plan on a trench at least 12 in wide and 18 to 24 in deep. Norfolk and LSU AgCenter agree on the 18 to 24 in depth but frame width differently. Penn State’s road guidance measures depth another way.

Trench, pipe and fabric details by source (regional guidance)
Detail Norfolk, VA (homeowner guide) LSU AgCenter (Louisiana) Penn State (road ditches)
Trench width At least 12 in 12 to 18 in Not covered here
Trench depth 18 to 24 in, set by pipe size and foundation depth 18 to 24 in Drain height plus at least 12 in of cover
Pipe 3 to 4 in perforated PVC or slotted corrugated, holes down Typically 4 in, at the trench base Optional; it adds capacity
Fabric Non-woven Class C, folded over the gravel, 12 in end laps Base and walls only Lightweight non-woven Class 1, double layer on top

Penn State’s Center for Dirt and Gravel Road Studies writes for road ditches, not yards, though it notes these stone underdrains are often called French drains. The archived NRCS Vermont standard 606 covers farm tile drainage. It calls for pipe at least 3 in in nominal diameter and at least 2 ft of cover in mineral soils.

Outside the US, a City of Edinburgh construction drawing sets a minimum width of the pipe diameter plus 300 mm. Trenches deeper than 1.5 m get the pipe diameter plus 450 mm. That is UK practice, shown only for contrast.

Which Gravel Size and Slope Do the Sources Use?

Stone size depends on the source: Norfolk uses 1/2 to 3/4 in gravel, LSU about 1 in, and Penn State 2 to 4 in for road underdrains. Only Norfolk gives a number for slope.

Stone size and slope rules by source Stone size: Norfolk, Virginia uses 1/2 to 3/4 inch gravel; LSU AgCenter in Louisiana uses about 1 inch; Penn State uses 2 to 4 inch clean stone, AASHTO number 1, for road underdrains. Slope: Norfolk asks for at least 1 inch per 8 feet, about 1.04 percent or 6.25 inches over 50 feet by our arithmetic; LSU says only enough to move the water; Penn State asks for continuous fall to the outlet with no percentage; the archived NRCS Vermont farm standard sets grade by flow velocity, at least 0.8 feet per second, or 1.4 where sediment is a risk. Stone size and slope rules by source Stone size (in) Norfolk, VA 1/2 to 3/4 in LSU AgCenter, LA about 1 in Penn State (road ditches) 2 to 4 in (AASHTO #1) 0 1 in 2 in 3 in 4 in Slope or fall rule Norfolk, VA At least 1 in per 8 ft About 1.04 percent 6.25 in over 50 ft LSU AgCenter, LA Enough to move the water No number given Penn State (roads) Continuous fall to the outlet No percentage given NRCS VT (farm, archived) Grade set by velocity: at least 0.8 ft per sec, 1.4 if sediment is a risk Percent and 50 ft figures are our arithmetic on Norfolk’s rule.
Norfolk writes for homeowners; Penn State’s large stone is for road ditches.

Here is the slope arithmetic (ours, not Norfolk’s). One inch per 8 ft is 1 in per 96 in, or about 1.04 percent. Over a 50 ft run, that is 50 / 8 = 6.25 in of fall. For comparison, an even 1 percent is 1.2 in per 10 ft.

The archived NRCS Vermont standard, written for farm fields, sets the minimum grade by flow speed instead. Water must move at least 0.8 ft per second, or 1.4 ft per second where sediment is a risk.

Fabric and Pipe Holes: Where the Guides Split

Most of these sources wrap the gravel in fabric, and Norfolk points the pipe holes down. Norfolk folds non-woven Class C geotextile over the gravel. WSU Clark County wraps weed cloth or geotextile over the gravel too. Penn State asks for enough fabric to make a double layer on top, fully encasing the stone.

LSU AgCenter is the outlier. Its publication 3879 puts fabric in the base and up the walls only. The gravel may run to the surface or sit under a thin layer of topsoil.

Pipe holes split the guides as well. Norfolk says holes facing down. The City of Edinburgh drawing in the UK puts perforations uppermost where a French drain and a surface-water drain are combined. Penn State treats the pipe as optional, adding capacity rather than being required. The archived NRCS farm standard says filter material must cover the pipe openings by at least 3 in.

None of these sources gives a US perforation size or pattern, so follow your local detail.

Gravel, Pipe and Fabric for a 50 ft Drain

A 50 ft drain that is 12 in wide and 18 in deep needs about 75 cu ft of gravel (2.78 cu yd), 53 ft of pipe and 250 sq ft of fabric, using the calculator’s default settings. Here is the hand check:

  • Gravel. 50 x 1 x 1.5 = 75 cu ft; 75 / 27 = 2.78 cu yd. At the tool’s 1.4 ton per cu yd setting, that is 3.89 tons. The 1.4 figure is a calculator setting labelled clean 3/4 in stone, not a figure from these sources.
  • Pipe. 50 x 1.05 = 52.5, rounded up to 53 ft. The 5 percent slack is a tool setting.
  • Fabric. Width = 1 + 2 x 1.5 + 1 = 5.0 ft, so 5 x 50 = 250 sq ft.

Three Adjustments to the Calculator’s Numbers

The tool’s totals are a starting point. Three adjustments from our own arithmetic bring them closer to a real build on the same 50 ft, 12 x 18 in trench.

  • Gravel stops short of the top. Norfolk ends the gravel 3 to 5 in below the top, so the gravel layer is 13 to 15 in deep. That is 54.2 to 62.5 cu ft. The tool fills the full depth, so treat 75 cu ft as a ceiling.
  • The pipe takes up space. A 4 in pipe has a cross-section of about 0.087 sq ft. That is about 5.8 percent of a 12 x 18 in trench, or roughly 4.4 cu ft over 50 ft. The tool does not subtract it.
  • Fabric needs laps. The trench perimeter is 1 + 1.5 + 1 + 1.5 = 5 ft, so 5 ft of fabric wraps it with no lap on top. Penn State’s double top layer needs at least 6 ft. Each Norfolk end joint adds at least 12 in of length.

Wider trenches widen the gap. An 18 in wide, 18 in deep trench at LSU’s upper width has a 6 ft perimeter, so measure your own trench before you order fabric.

Size your own trench

Enter your length, width and depth in the French Drain Calculator to get gravel, pipe and fabric, then adjust for fill depth and laps.

FAQs About Building a French Drain

Do the holes in French drain pipe go up or down?

Norfolk, Virginia says holes face down. A City of Edinburgh drawing in the UK puts them uppermost where a French drain and a surface-water drain are combined. Follow your local detail.

How deep should a French drain be?

Norfolk and LSU AgCenter both give 18 to 24 in for home drains. Norfolk ties the depth to pipe size and foundation depth. Penn State’s road guidance uses the drain’s height plus at least 12 in of cover.

How much slope does a French drain need over 50 feet?

Norfolk asks for at least 1 in per 8 ft, which is about 6.25 in over 50 ft by our arithmetic. LSU and Penn State give no number, only enough fall to move the water.

Should fabric go over the top of the gravel?

Most sources say yes. Norfolk, WSU Clark County and Penn State wrap the gravel, and Penn State wants a double layer on top. LSU AgCenter lines only the base and walls.

Can I use 2 inch stone in a yard French drain?

Penn State uses 2 to 4 in clean stone, but for road underdrains. Norfolk’s homeowner guide calls for 1/2 to 3/4 in washed gravel, and LSU uses about 1 in. Ask your local office.

Will a French drain work with a high water table?

Not where the water table is shallow. Norfolk says a test hole that fills with water means the water table is too shallow to build. WSU Clark County says these drains work best outside the groundwater table.

Do I need a permit to build a French drain?

It depends on where you live. None of these sources sets a national rule, so check with your local building or stormwater office. Either way, call 811 before you dig.

Sources and Further Reading

References Used in This Article

These rules come from Virginia, Louisiana, Pennsylvania, Washington and Vermont guidance, and they differ by place and purpose. They are not a design or a permit, so confirm the rules with your local office. Reviewed for accuracy by Prof. Dr. Khalil Mudassar, PhD. Last updated 2026-11-15.