Does a slab that looks dry look ready for flooring? Not always. Concrete can still hold moisture after its surface looks dry, so flooring and adhesive makers publish moisture limits.

Quick Answer

The moisture limit for flooring comes from the flooring or adhesive product sheet, which controls. The sheet names the test method and the limit. Two test methods appear in the sources here: a calcium chloride test under ASTM F1869 that measures vapor emission, and an in-slab relative humidity test under ASTM F2170.

Two Tests for Concrete Moisture Before Flooring

The two tests measure different things, so one result cannot stand in for the other. ASTM F1869 measures how much moisture vapor the slab gives off from its surface. ASTM F2170 measures relative humidity inside the slab.

Because the tests measure different things, a pass on one does not prove a pass on the other. Neither test is a substitute for the method the sheet names.

The calcium chloride test weighs a dish of calcium chloride before and after it sits on the slab for a set time. The weight gain converts into a rate, written as pounds per 1,000 square feet per 24 hours. The in-slab test places sensors in the concrete and reads the humidity they record.

The ASTM store pages give each standard’s scope, but the test steps sit in the full standards. This article did not read the full text of either standard, so check the procedure there before you test.

Once you have a dish result, the concrete moisture calculator converts it into the pounds per 1,000 square feet per 24 hours figure. The limits discussed below use that unit, so check your sheet for the same one.

Where the Moisture Limit Really Comes From

The flooring or adhesive product sheet sets the limit, and that sheet controls the job. Armstrong’s commercial instructions take the limit from the product. Its LUXE residential instructions use a calcium chloride limit of 5 lb.

The moisture calculator also uses 3 lb as its default. That figure is a calculator default, not a product limit, so it does not decide the answer for your floor.

Where the sheet gives a limit in a different unit, or for a different method, do not convert it by guesswork. Ask the flooring or adhesive maker for written guidance before you install. A written answer from the maker settles the number far better than a rule of thumb.

Moisture limits and test methods by source
Source Test method Limit Status of the figure
Armstrong commercial instructions In-slab RH (ASTM F2170), the preferred method Set by the product The product sheet controls
Armstrong LUXE residential instructions Calcium chloride (ASTM F1869) 5 lb per 1,000 sq ft per 24 hours Product sheet figure
Concrete moisture calculator default Calcium chloride 3 lb per 1,000 sq ft per 24 hours Secondary figure, not a product limit

Armstrong also publishes a moisture limit table on an adhesive page. That table did not extract cleanly, so this article does not use its figures. Check the page yourself before you rely on any value from it.

To read your own sheet, find three things: the test method, the limit, and the unit. Compare numbers only when the units match.

Working Through a Calcium Chloride Example

A dish gain of 1.8 grams over 72 hours, on a 0.4449 square foot dish, gives about 2.97 lb per 1,000 square feet per 24 hours. That passes a 3 lb limit with 0.03 lb to spare, and it passes a 5 lb limit with 2.03 lb to spare.

The work has three steps. Each step is hand-checked below, with the rounding shown.

  1. Convert grams to pounds. 1.8 / 453.592 = 0.00397 lb.
  2. Divide by the dish area. 0.00397 / 0.4449 = 0.00892 lb per square foot over 72 hours.
  3. Scale to 1,000 square feet and 24 hours. 0.00892 x 1,000 x 24 / 72 = 2.97 lb.

Run the same numbers without rounding and you get the same answer. The top line is 1.8 x 24 x 1,000, or 43,200. The bottom line is 453.592 x 0.4449 x 72, or 14,529.8. Then 43,200 divided by 14,529.8 is 2.97.

A reverse check confirms the answer. Scale 2.97 lb back down to the dish: 2.97 x 0.4449 / 1,000 x 3 = 0.00396 lb, which is 1.80 grams. That matches the reading you started with.

Example result against two moisture limits Three bars on a 0 to 5 lb scale, in pounds per 1,000 square feet per 24 hours. The example result is 2.97 lb. The calculator default limit is 3 lb, a secondary figure and not a product limit. The Armstrong LUXE residential limit is 5 lb. The example passes both, with 0.03 lb of room under 3 lb and 2.03 lb under 5 lb. Example result against two moisture limits Example result 2.97 lb 3 lb (calculator default) 3 lb 5 lb (Armstrong LUXE) 5 lb 0 1 2 3 4 5 Scale: lb per 1,000 sq ft per 24 hours. Calculator default is not a product limit.
The example passes both limits. Only the product sheet sets the limit for your floor.

Treat this as a worked example, not a boundary. The thin 0.03 lb margin under 3 lb does not show where a pass turns into a fail. The product sheet decides what a result that close means.

The dish area matters more than it looks. Rounding 0.4449 square feet to 0.44 raises the same gain to 3.01 lb, because 43,200 divided by 453.592 x 0.44 x 72 is 3.01. Use the exact area of your own dish in every calculation.

When the In-Slab Probe Test Is the Better Fit

Armstrong’s commercial instructions prefer the in-slab probe test, ASTM F2170, over the calcium chloride test. Use the method your sheet names, even when the other test looks simpler.

The probe test reads humidity inside the slab, so it answers a question the calcium chloride test does not. A result from one method does not replace a result the sheet requires from the other.

Book the test before the flooring date is fixed. A failed result changes the schedule, and a test booked late leaves less room to respond.

Use this checklist before you book a test:

  • Find the method the sheet names. This article covers ASTM F1869 and ASTM F2170 only.
  • Run that method only. Do not swap in the other test to get a friendlier number.
  • Match the units. Confirm the sheet and your result use the same unit before you compare them.
  • Save the full report. Keep the test report with the job file so the flooring crew can see it.

What to Do If a Slab Fails the Limit

When the slab tests above the sheet’s limit, you have two broad options: dry the slab and retest, or use a mitigation product that the sheet allows. The dry-and-retest path needs a fresh result before you install.

This article does not verify a drying time. The one-month-per-inch rule and the 75 percent RH figure are not verified here as standards.

Write down the test date, the method, the result, the unit and the limit it was compared with. A short record makes it easier to explain a retest to the flooring maker, the installer or the client.

What to do after a moisture test A planning flow, not a code rule. Step one is to run the test the product sheet names. Step two asks whether the result is at or below the sheet limit. If yes, install following the sheet. If no, dry the slab and retest, or use a mitigation product the sheet allows. The flow gives no drying time. After a moisture test: a planning flow Run the test the sheet names At or below the sheet limit? Yes Install following the sheet No No: dry the slab and retest or use a product the sheet allows Planning flow for this article, not a code rule. Drying time is not verified here. The product sheet controls the limit.
Both branches end at the product sheet, which sets the limit.

The LATICRETE NXT Vapor Reduction Coating datasheet makes product claims about reducing vapor. Those are the manufacturer’s claims, not results this article checked. Confirm the product is allowed by your flooring sheet before you buy.

Coatings or sealers may also be on your list. For the timing side of that decision, read our guide on sealing new concrete.

Check your own dish numbers

Enter your dish result into the moisture calculator for your dish test, then compare the output with your product sheet.

FAQs About Testing Concrete Moisture

What is the difference between the calcium chloride test and the probe test?

The calcium chloride test (ASTM F1869) measures how much moisture vapor the slab gives off over time. The probe test (ASTM F2170) measures relative humidity inside the slab. The two results are not interchangeable.

Where does my moisture limit come from?

The flooring or adhesive product sheet sets the limit, and that sheet controls. Read the test method, the limit and the unit printed there before you run any test.

Is 75 percent relative humidity the standard for flooring?

This article did not verify 75 percent relative humidity as a standard. Use the limit printed on your product sheet instead, because that is the number your installation must meet.

Is 3 lb the right limit for my floor?

Not necessarily. The 3 lb figure is the calculator default, a secondary figure. Armstrong’s LUXE residential instructions use 5 lb. Your own product sheet sets the limit for your floor.

If my sheet names the calcium chloride test, can I run a probe test instead?

Run the method the sheet names. A result from the other method does not count unless the product sheet says it does.

How do I convert a dish result to pounds per 1,000 square feet?

Convert grams to pounds, divide by the dish area, then scale to 1,000 square feet and 24 hours. A 1.8 gram gain on a 0.4449 square foot dish over 72 hours gives 2.97 lb.

What should I do if my slab is over the limit?

Dry the slab further and retest, or use a mitigation product that your flooring sheet allows. This article does not verify a drying time, so the retest result decides when to proceed.

Sources and Further Reading

References Used in This Article

The moisture limit comes from the flooring or adhesive product sheet, which controls. The 75 percent RH figure and the one-month-per-inch rule are not verified here. Reviewed for accuracy by Prof. Dr. Khalil Mudassar, PhD. Last updated 2026-11-11.