Can a cedar shake roof go on a house in a wildfire zone? The answer depends on the cedar shake fire rating your code requires and on where the house sits. Here is what the California text says, and where it stops.
The answer depends on your local code. The 2022 California Building Code, Chapter 7A, requires roof assemblies in Fire Hazard Severity Zones to carry a Class A rating under ASTM E108 or UL 790. In the 2016 code, the Class A rule for Very High Fire Hazard Severity Zones sat in Chapter 15, not Chapter 7A. Neither text read for this article bans wood shakes outright.
Cedar Shake Fire Rating: What Class A Means
A Class A rating is a fire result for a roof assembly, tested under ASTM E108 or UL 790. The 2022 California text read for this article uses that test as its standard in Fire Hazard Severity Zones. The rating applies to the assembly, not to the shake by itself.
The code uses three class labels, A, B, and C. The diagram below lists them only and makes no claim about cedar shakes. For shake quantities, the Cedar Shake Calculator is a separate tool with a separate job.
What Chapter 7A Requires in Fire Hazard Zones
The 2022 edition of California Chapter 7A, read through an up.codes mirror, requires a Class A rating for roof assemblies in Fire Hazard Severity Zones. The mirror is not the official publication. Check the wording against the official text before you rely on it.
The 2016 edition splits the rule across two chapters. Its Chapter 7A roof section says roof assemblies must be installed in line with their listing. Section 1505.1.1 in Chapter 15, read through the same mirror, requires a fire-retardant roof covering of at least Class A in Very High Fire Hazard Severity Zones when more than 50 percent of the roof is replaced within one year. Section 1505.1.2 sets at least Class B in State Responsibility Areas. Its scope covers new buildings with permit applications on or after July 1, 2008, in any Fire Hazard Severity Zone or Wildland Interface Fire Area.
| Topic | 2016 edition | 2022 edition |
|---|---|---|
| Base code | Adopts IBC 2015 with California amendments | Adopts IBC 2021 with California amendments |
| Roof rating in Fire Hazard Severity Zones | Chapter 7A: roof assemblies installed in line with their listing. Chapter 15, Section 1505.1.1: at least Class A in Very High zones when over half the roof is replaced in a year | Class A required under ASTM E108 or UL 790 |
| Fire-retardant-treated shingles and shakes | Must be approved and listed by the State Fire Marshal | Same listing requirement in the text read |
| Scope named in the text read | New buildings with permit applications on or after July 1, 2008, in any Fire Hazard Severity Zone or Wildland Interface Fire Area | Roof rule for Fire Hazard Severity Zones; the page was cut off, so later sections were not read |
Some secondary sites say the Class A rule covers only Very High zones. The 2022 text read here names Fire Hazard Severity Zones without a Very High limit. Read the full text, and your local map, before you assume a narrower scope.
Many blogs and vendors say wood shakes are banned in very high fire zones or wildland areas. The text read for this article does not say that. It sets a Class A rating for roof assemblies and says nothing about a wood-specific ban. The ban claim is not verified here.
Do Fire-Retardant-Treated Shakes Qualify?
Whether fire-retardant-treated (FRT) shakes reach Class A is not settled by the text read here. Both editions say FRT shingles and shakes must be approved and listed by the State Fire Marshal. Sources disagree about what that listing allows.
- Treated shakes can qualify. Vendor material and a university extension search snippet say treated shakes can reach Class A in an assembly with a specified underlayment.
- Treated shakes are barred. Several blogs make this claim.
- Treated shakes generally cannot qualify. A patent document says treated shakes generally cannot reach Class A.
None of these claims was checked against an official text. Treat FRT shakes as an open question until the State Fire Marshal listing or your local authority confirms what is allowed.
Local Rules Decide Your Roof
The state code sets a baseline, and local amendments can add to it or change it. Start with the Fire Hazard Severity Zone map for your address. Then ask the building department which code edition and amendments apply to your project.
- Look up whether the parcel sits inside a Fire Hazard Severity Zone.
- Ask which edition of Chapter 7A your city or county enforces.
- Ask whether a Class A roof assembly is required, and which listing it must carry.
- Get the answer in writing before you order shakes.
Where the Cedar Shake Calculator Fits
Fire rating and shake quantity are separate questions. The calculator on this site estimates bundles, roofing squares, and ridge units. It does not check fire classification. The page cites Cedar Shake and Shingle Bureau coverage tables, which this article did not read.
The tool’s own worked example uses a 2,000 sq ft roof, 24 in shakes, 10 in exposure, 10% waste, and 60 ft of hip and ridge. The live page showed 110 field bundles, 20.0 squares, 100 bundles before waste, and 4 ridge bundles on 2026-11-12. The steps below repeat that arithmetic.
- Squares. 2,000 / 100 = 20 squares.
- Before waste. 20 x 5 = 100 bundles, since 24 in shakes at 10 in exposure take 5 bundles per square.
- Field bundles. 100 x 1.10 = 110 bundles with 10% waste.
- Ridge. One ridge bundle covers 20 x 10 / 12 = 16.67 ft. 60 / 16.67 = 3.6, rounded up to 4 bundles.
These are the tool’s arithmetic examples, not a fire-rated roof plan. The page says 18 in shakes allow a 7.5 in maximum exposure at 4:12 pitch and steeper. The tool does not list 18 in shakes at 10 in exposure, and it does not block that choice. The result for that combination is not documented.
Enter your roof area and ridge length in the Cedar Shake Calculator for bundle counts. It sizes the order only. Ask your building department about fire classification.
FAQs About Cedar Roofs and Wildfire Zones
Does California require Class A roofs in wildfire zones?
The 2022 California Building Code, Chapter 7A, as read through a mirror, requires Class A roof assemblies in Fire Hazard Severity Zones. In the 2016 code, the Class A rule for Very High Fire Hazard Severity Zones sat in Chapter 15, not Chapter 7A. Check which edition your city or county enforces.
What does Class A mean for a roof?
Class A is a fire rating for a roof assembly, tested under ASTM E108 or UL 790. The 2022 text read here requires it in Fire Hazard Severity Zones. The rating covers the whole assembly, not the shake alone.
Are fire-retardant-treated cedar shakes allowed?
That is not settled by the text read here. Both editions require FRT shingles and shakes to be approved and listed by the State Fire Marshal. Sources disagree on whether treated shakes reach Class A.
Is a wood shake roof banned in wildfire zones?
The text read for this article does not show a ban on wood shakes. Many blogs make that claim, but it is not verified here. Ask your building department about any roof restriction for your address.
Does the 2016 code apply to a new house?
The 2016 text covers new buildings with permit applications on or after July 1, 2008, in any Fire Hazard Severity Zone or Wildland Interface Fire Area. Your locally adopted edition decides what applies to your project.
How do I find out if my address is in a Fire Hazard Severity Zone?
Start with the Fire Hazard Severity Zone map for your area, then ask your local building department to confirm the zone for your parcel. This article did not verify any specific map or office.
Does the Cedar Shake Calculator check fire ratings?
No. The calculator estimates bundles, roofing squares, and ridge units from roof area, exposure, and waste. Fire classification comes from the code and your local building department.
Sources and Further Reading
References Used in This Article
- California Building Code 2022, Chapter 7A, read via up.codes mirror (not the official text), accessed 2026-11-12.
- California Building Code 2016, Chapter 7A, read via up.codes mirror (not the official text), accessed 2026-11-12.
- California Building Code 2016, Chapter 15, Roof Assemblies, read via up.codes mirror (not the official text), accessed 2026-11-15.
The roof classification rules here are from California code text read through a mirror. Check the edition your jurisdiction adopts and your local fire authority before you choose a roof. Reviewed for accuracy by Prof. Dr. Khalil Mudassar, PhD. Last updated 2026-11-15.

Shakeel Muzaffar is the Founder and Editor-in-Chief, with over 15 years of experience in digital publishing and online tool development. He oversees editorial quality and formula verification to ensure accurate, practical, and easy-to-use calculators.